E Encoder User’s Manual Setup and Status Checks
Table 3-3 TC, Fault, Remote, PCM Dly, Error, and VRef LEDs
Name Indication
TC
Green: Valid timecode signal.
Yellow: Frame rate does not match video reference.
Off: No TC signal detected.
Fault
Red: Hardware-related fault condition.
Off: No fault condition.
Remote
Not used in this version of the software.
PCM Dly
Green: Valid PCM signal.
Yellow: Non–48 kHz signal.
Off: No PCM signal.
Error
Red: Input not valid for current settings.
Off: No error condition.
Green: Lock with a valid analog composite video signal.
Yellow: The video reference does not match the selected
frame rate in the DP571.
Flashing Red: The internal clock is not locked to the incoming
reference.
VRef
3.7.4 Input Channel Activity
The DP571 input channel activity LEDs display the number of channels in the
currently selected program configuration, as well as their status. An LED lights up for
each channel in use, and its color indicates its status. Details are listed in Table 3-4.
Table 3-4 Channel Activity LEDs
State Indication
Yellow Channel enabled; level <–60 dBFS.
Green Channel enabled; level –60 dBFS.
Red
Channel enabled; level –0.1 dBFS.
This indication can be triggered by a
single sample.
Channel not used in the selected
program configuration.
Off
Flashing Yellow
Channel sample frequency out of range,
or no input present.
3.8 Using the Status Connector
The GPIO Status connector on the rear panel is a standard 9-pin female D-connector.
Signal details are given in Section
6.2.1.