Dolby Laboratories DP524 Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Systemy kontroli dostępu bezpieczeństwa Dolby Laboratories DP524. Dolby Laboratories DP524 Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 40
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Artisan Technology Group is your source for quality
new and certied-used/pre-owned equipment
FAST SHIPPING AND
DELIVERY
TENS OF THOUSANDS OF
IN-STOCK ITEMS
EQUIPMENT DEMOS
HUNDREDS OF
MANUFACTURERS
SUPPORTED
LEASING/MONTHLY
RENTALS
ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
REMOTE INSPECTION
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specications, manuals, and documentation
Contact us: (888) 88-SOURCE | sales@artisantg.com | www.artisantg.com
SM
View
Instra
Przeglądanie stron 0
1 2 3 4 5 6 ... 39 40

Podsumowanie treści

Strona 1 -

Artisan Technology Group is your source for quality new and certied-used/pre-owned equipment• FAST SHIPPING AND DELIVERY• TENS OF THOUSANDS OF IN-S

Strona 2 - Model DP524

1-31.4 Data Rates, Sample Rates and ChannelsPossible AC-3 Data Rates, Sample Rates and Number of ChannelsData Rate Sample rate Channels40 kbps 32kHz,

Strona 3

1-41.5 Regulatory NoticesFCCThis equipment has been tested and found to comply with the limits for a Class Adigital device, pursuant to part 15 of the

Strona 4

1-5IEC NOTICESIMPORTANT SAFETY NOTICEThis unit complies with the safety standard IEC65. To ensure safe operation and to guardagainst potential shock

Strona 5

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Strona 6 - TABLE OF CONTENTS

SECTION 2APPLICATIONSThe Dolby Model DP524 is suitable for a variety of point-to-point and point-to-multipoint digital transmission applications, incl

Strona 7

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Strona 8 - 1.1 Introduction

SECTION 3PRE-INSTALLATION3.1 UnpackingBefore proceeding further, be sure to inspect the outer carton for shipping damage.If there has been any penetra

Strona 9 - 1.3 Dolby AC-3 and AC-2

3-2OPEN THEDOORACTIVEFUSE CARRIER(LOWER)FUSECheck that the fuse in the active (lower) fuse carrier is of the correct rating. A sparefuse can be stored

Strona 10

3-3front, rear, and each of the sides of the unit. The three black screws shouldbe reserved for affixing at the front.Note The front panel is attached

Strona 11 - 1.5 Regulatory Notices

3-43.4.1 Jumpers for Encoded Data In & Timing (J103)Receive Timing J205 / Receive Data J206 [terminated]Termination resistors (150 ohms) are prov

Strona 12 - IEC NOTICES

Model DP524Two-Channel AC-2 / AC-3Digital Audio DecoderUsers' ManualArtisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-

Strona 13

3-5Note Switch positions 5 and 6 take on two roles:• They set the Aux Data output baud rate when S101-2 is in the Normal position and S101-4 is in th

Strona 14 - 2.2 Telecommunications

3-63.5.3 Switch no. 3 - Digital Output Format Selection [up]Position this switch to corresponds to the type of digital output signal format. Referto S

Strona 15

SECTION 4INSTALLATION4.1 MountingThe DP524 is designed for 19 inch rack mounting, but may be mounted in any planeand with any orientation. It occupies

Strona 16 - 3.3 Fusing Information

4-2For optimum immunity to radio-frequency interference, cable shields must beconnected to the shells of the XLR connectors, not to pin 1.In an instal

Strona 17 - Internal Fuse

4-3Baud Rate S101-5 S101-60 Down Down1200 Down Up2400 Up Down9600 Up UpWhere is baud rate of the Encoder (generating the Aux data stream) ishigher tha

Strona 18 - DP524 MOTHERBOARD

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Strona 19

SECTION 5OPERATIONOnce the DP524 is installed and operational, no user-intervention is required. Innormal operation, one of the Green LEDs will indica

Strona 20

5-25.2 Rear Panel Level ControlsEach analog output connector has a level control adjacent to it. Each analog outputis adjustable (at full scale) over

Strona 21

SECTION 6INTERFACE SPECIFICATION AND DESCRIPTION6.1 DP524 Interface SpecificationsAES/EBU Digital Audio Output, J101XLR-type connector, 5V p-p typical

Strona 22 - 4.2 Audio Connections

6-2Status / Control, J104, 25-pin D-connector:Pin Connection Comments1 NC Do Not Connect2 NC Do Not Connect3 NC Do Not Connect4 NC Do Not Connect5 NC

Strona 23 - 4.3.2 RS-232 (J105)

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Strona 24 - 4.3.3 RS-422 (J106)

6-36.2 RS-449 Interface Description6.2.1 Functional DescriptionThe Dolby Model DP524 provide a standard RS-449 interface in the type DT mode(data and

Strona 25

6-46.2.3 Back-to-Back TestingFor purposes of testing the Model DP523 and Model DP524 in a back-to-backconfiguration, a special cable must be construc

Strona 26 - OPERATION

6-56.3 Serial ControlIt is possible to command the DP524 via the RS-232 port, J105 on the rear of theunit when the Command/Aux data switch (S101-4) is

Strona 27 - 5.3 Test Tone Level

6-6Command $18: Return System Status$FB $20 $18 0 $FDThe unit returns the following byte:B7 B6 B5 B4 B3 B2 B1 B00 Dr_lock Sr_lock Test 48kHz 44.1kHz 3

Strona 28 - SECTION 6

6-7This command will return $FF if the decoder is in Test Tone mode or if thedecoder is in normal mode but does not have an input data clock that it c

Strona 29 - XLR-type connectors

6-8Command $42: Set Compression mode$FB $20 $42 data $FDWhere data is as follows:B7 B6 B5 B4 B3 B2 B1 B0000000C1C0C0 and C1 are defined as follows:C1

Strona 30 - 6.2.2 Interface Timing

SECTION 7DP524 SPECIFICATIONSpecifications1Italics = nomenclature for panel markings, switch labels, jumpers, LEDs, etc.All inputs and outputs are TT

Strona 31 - 6.2.3 Back-to-Back Testing

7-2Digital Audio OutputsAES/EBU, 3-pin XLR-type, male, balanced , 110 ohms ±5%, 5Vpp nominal.S/PDIF, BNC female connector, unbalanced, 75 ohms ±5%,

Strona 32 - 6.3 Serial Control

7-3GeneralPower Requirements90-260 VAC, 50-60 Hz, 24VADimensions and Weight1- ¾ x 19 x 11- ¾ inches (4.45 x 48.26 x 29.8 cm), 8.5 pounds (3.9 kg), app

Strona 33

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Strona 34 - 6.3.2 AC-3 Related commands

Users' ManualForModel DP524AC-2 / AC-3 Two-ChannelDigital Audio DecoderDolby Laboratories IncorporatedU.S.A. 100 Potrero Avenue, San Francisco,

Strona 35

Artisan Technology Group is your source for quality new and certied-used/pre-owned equipment• FAST SHIPPING AND DELIVERY• TENS OF THOUSANDS OF IN-S

Strona 36 - DP524 SPECIFICATION

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Strona 37

TABLE OF CONTENTSSECTION 1 Introduction1.1 Introduction ...

Strona 38

SECTION 6 Interface Specification and Description6.1 DP524 Interface Specifications...

Strona 39

SECTION 1INTRODUCTION1.1 IntroductionThe Dolby Model DP524 is a digital audio decoder unit supporting both Dolby AC-2 and Dolby AC-3 digital audio cod

Strona 40

1-21.2 Features• Automatic algorithm, data rate and sample rate selection• Dolby AC-3 audio coding algorithm from 40 kbps - 384 kbps• Mono, Dual-Mono